GENERATOR CONTROL &

PROTECTION SYSTEMS MAINTENANCE

 

can evaluate your problem; consult with you on solutions; test your equipment; maintain your system; train your maintenance personnel; and, if needed, help you retrofit key components to your existing system.

[see Retrofits and Upgrades]

The Maintenance Program will provide greater reliability through the full load capabilities of your generating system, enhance unit performance, improve in-house system troubleshooting ability and help reduce overall O&M costs.

recommends the following maintenance services directed to the specific Generator Control & Protection Systems at your site:

  • Component Inspection, Cleaning & Testing    

  • Protective Relay Calibration
  • Auto Synch / Synch Check System Calibration
  • Unit Trip Test
  • Meter and Transducer Calibration
  • Control Sequence Checks
  • 52G Generator Breaker Mechanical Checks
  • 41E Field Breaker Mechanical Checks
  • Generator PI Testing
  • Generator Power Factor Insulation Testing
  • CT & PT Signal Transformer Tests
  • Neutral Grounding Transformer Tests
  • Excitation Transformer Tests

  • V-Reg Dummy Load Simulation/Operational Tests
  • Excitation System Tune-up - Stability, Range, Gain
  • Protection Module (64F, 59E, Field OC, etc.) Tests
  • Limiter Proof Tests (Max Ex, Min Ex, V/Hz, etc.)
  • Power Rectifier Bridge Tests, including Waveform Analysis
  • Generator performance Testing
  • System "Hands-On" Refresher Training   [see Training]
  • Appraisal Report - System Settings, Data, Summary & Recommendations

has had direct field experience on Generating Units ranging from 70 Kilowatts through 1,300 Megawatts.  has provided demonstrated expertise on the maintenance & troubleshooting of the following Generator Control & Protection Systems associated with those machines:

  • Frame 5, 6, 7 & 9 Gas Turbines with:
    • GE Type SCT-PPT Static Excitation Systems (Frame 5 & 7)
    • GE Type Potential Source Excitation Systems
    • GE Type Shunt SCR Potential Source Static Excitation System
    • GE Type EX2000 Digital Static Excitation Systems (Frame 5 & 7)
    • GE Type DS3820SVR Voltage Regulator Systems (Frame 5)
    • GE Type 3GFA Carbon Pile Voltage Regulator Systems (Frame 5)
    • Basler Type SSE Static Excitation Systems (Frame 5 & 7)
    • Basler Digital DECS-300 / SSEN Static Excitation Systems (Frame 5 & 7)
    • Basler Type DECS-300 V-Reg on GE Type SCT-PPT Static Excitation Systems (Frame 5 & 7)
    • GEC-Alsthom Static Excitation System (Frame 5)

    • Hitachi Type HIGEX Static Excitation System

  • 251 & 501 Gas Turbines with:

    • Westinghouse Type POWERTREX (PRX) Voltage Regulator System

  • LM2500 & LM5000 Gas Turbines with:

    • GE Type Potential Source Excitation Systems

  • Steam Turbines with:

    • GE Type ALTERREX Static Excitation Systems

    • GE Type ALTHYREX Static Excitation Systems

    • GE Type GENERREX Static Excitation Systems

    • GE Type SCT-PPT Static Excitation Systems

    • GE Type SCPT Static Excitation Systems

    • GE Type AMPLIDYNE Voltage Regulator Systems

    • GE Type DS3820SVR Voltage Regulator Systems

    • GE Type 3S7930SA SCR Voltage Regulator Systems

    • GE Type 3GFA Carbon Pile Voltage Regulator Systems

    • Siemens Type EX-1 Static Excitation Systems

    • Basler Type SSE Static Excitation Systems

    • Basler Digital Type DECS-300 / SSEN Static Excitation Systems

    • Basler Type SR8A Voltage Regulator Systems

    • Westinghouse Type WTA Static Excitation Systems

    • Westinghouse Type POWERTREX (PRX) Excitation Systems

    • Westinghouse Type WMA Excitation Systems

    • Westinghouse Type MAGASTAT Excitation Systems

    • Westinghouse Type BJ-30 Voltage Regulator Systems

    • Westinghouse Type SILVERSTAT Voltage Regulator Systems

    • Westinghouse Type ROTOTROL Voltage Regulator Systems

    • GEC-Alsthom Voltage Regulator

    • Allis Chalmers Type REGULEX Excitation Systems

  • P&W Twin Pac Gas Turbines with:

    • EM Type Voltage Regulator Systems

    • Basler Type DECS-15 Digital Voltage Regulator Systems

  • Diesel Turbines with:

    • EMD Vickers Type Excitation Systems

    • Basler Type SR4A / SR8A / SSR Voltage Regulator Systems

  • Hydroelectric Turbines with:

    • GE Type Potential Source Static Excitation systems

    • GE Type 3S7930SA SCR Voltage Regulator Systems

    • Basler Type SSE Static Excitation Systems

    • Basler Type SR4A / SR8A Voltage Regulator systems

    • Siemens Type EX-1 Static Excitation System

  • Protective Relay Systems including:

    • General Electric Electro-Mechanical Relays

    • General Electric Solid-State Relays

    • General Electric Generator Multifunction Protection Modules

    • Beckwith Electric Generator Multifunction Protection Modules

    • Basler Electric Solid-State Relays

    • Basler Electric Generator Multifunction Protection Modules

    • Basler Electric Multifunction Overcurrent Protection Modules

    • Basler Electric Multifunction Differential/OC Protection Modules

    • Schweitzer Engineering Multifunction Overcurrent Protection Modules

    • Schweitzer Engineering Multifunction Differential Protection modules

    • Schweitzer Engineering Multifunction Generator Protection Modules

    • Westinghouse / ABB Electro-Mechanical Relays

    • Westinghouse / ABB Solid-State Relays

    • Toshiba Electro-Mechanical Relays

  • Automatic Synchronizing Systems including:

    • General Electric Electro-Mechanical auto Synch & Synch Check Relays

    • Beckwith Electric M0193 / M0194 Generator Control & Auto Synch Module

    • Beckwith Electric M0188 Solid-State Synch Check Relays

    • Basler Electric Type BE1-25A Automatic Synchronizing Module

    • Basler Electric Type BE1-25 Solid-State Synch Check Relay

Consider as the support source for all of your GENERATOR CONTROL & PROTECTION SYSTEMS MAINTENANCE requirements.  Services are available nationwide and internationally.