GENERATOR PROTECTION UPGRADE

How would you like to REPLACE 10 or more of your protective relays with ONE digital relay and also reduce the cost of having them calibrated every 3 years???

Let E-Squared help you get from here:

e2psi_1.gif (94045 bytes)

To Here:

has design & field engineering experience at applying Generator Relay Protection Modules (Beckwith Electric Co. / Basler Electric Co. / General Electric Co. / Schweitzer Engineering) to replace a minimally protected system utilizing the old, existing electro-mechanical type generator protection relays such as the following:

21   Distance Relay               46    Current Negative Sequence Relay

24   Volts Per Hertz Relay    47    Voltage Phase Sequence Relay

25   Synch Check Relay       51V  OC Relay with Voltage Restraint

25A Auto Synch Relay         59    Overvoltage Relay

27   Undervoltage Relay       64G  Generator Ground Relay

32   Reverse Power Relay   81    Over/Under Frequency Relay

40   Loss of Excitation          87G Current Differential Relay

       Relay

 

 

 

offers "Technical Direction / Design Interface" or "Turnkey Installation" Packages with regard to Generator Protection System Upgrades.

Project Tasks can include:

  • Site Demolition Activities

  • System Fault Studies

  • Relay Protection Module Settings

  • Auto Synch Module Settings

  • Design Interface

  • System Drawings (Elementary, Connection & Interconnection)

  • Site Installation Activities

  • Relay Protection Module Testing & Calibration Checks

  • Communication Interface

  • System "Trip" Testing

  • System Off-Line Synch Phasing Tests

  • System On-Line CT/PT Signal Input Phasing Checks

 

 

Advantages to applying and installing these new Generator Relay Protection Modules:

  • Better System Protection Flexibility

  • More Independent Functions Available

  • Small Packaging for panel or rack mount

  • LCD Displays with real time metering and system monitoring

  • Communication Ports for metering, alarms and fault data monitoring from remote locations

  • Project Cost Saver (yearly maintenance and calibration testing time is greatly reduced)

  • Replacement Costs (costs for an electro-mechanical "40" Loss of Excitation Relay is greater than one Protection Module)

 

 

Recent Generator Protection System Upgrade Projects Completed by include:

  • Turnkey Upgrade Project on (2) GE Frame 7 Gas Turbine-Generator Units;

    • GE Type SR-487 Generator Protection Module

    • Beckwith Type M3425 Protection Module (as backup)

    • Basler Type BE1-25A Auto Synch Module

    • Basler Type BE1-25 Synch Check Relay

     

  • Turnkey Upgrade Project on (2) 40 MVA Steam Turbine-Generator Units;

    • Schweitzer Engr. Type SEL-300G Generator Protection Module

    • Schweitzer Type SEL-387 Current Differential Module

  • Supply / Design Interface / Technical Direction Upgrade Project on (4) Hitachi Frame 5 Gas Turbine-Generator Units;

    • Beckwith Type M3425 Protection Module

    • Basler Type BE1-25A Auto Synch Module

    • Basler Type BE1-25 Synch Check Relay

     

  • Design Interface / Technical Direction Upgrade Project on a GE Frame 5 Gas Turbine-Generator Unit;

    • Schweitzer Engr. Type SEL-300G Generator Projection Module

    • Beckwith Type M3420 Generator Protection Module

    • Basler Type BE1-25A Auto Synch Module

    • Basler Type BE1-25 Synch Check Relay

     

  • Turnkey Upgrade Project on (10) GE Frame 7 Gas Turbine-Generator Units;

    • Beckwith Type M3420 Generator Protection Module

    • Basler Type BE1-25A Auto Synch Module

    • Basler Type BE1-25 Synch Check Relay

    • Schweitzer Engr. Type SEL-501 Overcurrent Protection Module

    • Basler Type BE1-851 Overcurrent Protection Module

    • Schweitzer Engr. Type SEL-387 Current Differential Module

  • Turnkey Upgrade Project on (2) Hitachi Frame 5 Gas Turbine-Generator Units;

    • GE Type SR-487 Generator Protection Module

    • Basler Type BE1-25 Synch Check Relay

  • Turnkey Upgrade Project on (3) GE Frame 5 Gas Turbine-Generator Units;

    • Beckwith Type M3420 Generator Protection Module

    • Beckwith Type M0193/M0194 Generator Control and Auto Synch Modules

    • Beckwith Type M0188 Synch Check Module

  • Design Interface / Technical Direction Upgrade Project on a 2 MVA Diesel-Generating Unit

    • Basler Type BE1-GPS100 Generator Protection Module

    • Basler Type BE1-25A Auto Synch Module

    • Basler Type BE1-25 Synch Check Relay

Call or email Jill Kelsic to request pricing information and/or Reference Contacts with regard to Generator Protection Upgrade Projects.

Return to Generator Control & Protection Upgrades

 